IBM Integration Bus 9.0 and 10.0 transmits user credentials in plain in clear text which can be read by an attacker using man in the middle techniques. IBM X-Force ID: 134165.
Search vulnerabilities
In the "NQ Contacts Backup & Restore" application 1.1 for Android, no HTTPS is used for transmitting login and synced user data. When logging in, the username is transmitted in cleartext along with an SHA-1 hash of the password. The attacker can either crack this hash or use it for further attacks where only the hash value is required.
An issue was discovered in certain Apple products. The Apple Support app before 1.2 for iOS is affected. The issue involves the "Analytics" component. It allows remote attackers to obtain sensitive analytics information by leveraging its presence in a cleartext HTTP transmission to an Adobe Marketing Cloud server operated for Apple, as demonstrated by information about the installation date and time.
Mirasys Video Management System (VMS) 6.x before 6.4.6, 7.x before 7.5.15, and 8.x before 8.1.1 has a login process in which cleartext data is sent from a server to a client, and not all of this data is required for the client functionality.
Foreman: API permits HTTP requests when require_ssl is enabled
Foreman after 1.1 and before 1.9.0-RC1 does not redirect HTTP requests to HTTPS when the require_ssl setting is set to true, which allows remote attackers to obtain user credentials via a man-in-the-middle attack.
krb5: Metadata taken from the unauthenticated plaintext
Heimdal before 7.4 allows remote attackers to impersonate services with Orpheus' Lyre attacks because it obtains service-principal names in a way that violates the Kerberos 5 protocol specification. In _krb5_extract_ticket() the KDC-REP service name must be obtained from the encrypted version stored in 'enc_part' instead of the unencrypted version stored in 'ticket'. Use of the unencrypted version provides an opportunity for successful server impersonation and other attacks. NOTE: this CVE is only for Heimdal and other products that embed Heimdal code; it does not apply to other instances in which this part of the Kerberos 5 protocol specification is violated.
An Information Exposure issue was discovered in ProMinent MultiFLEX M10a Controller web interface. When an authenticated user uses the Change Password feature on the application, the current password for the user is specified in plaintext. This may allow an attacker who has been authenticated to gain access to the password.
The Vibease Wireless Remote Vibrator app for Android and the Vibease Chat app for iOS use cleartext to exchange messages with other apps and the PLAIN SASL mechanism to send auth tokens to Vibease servers, which allows remote attackers to obtain user credentials, messages, and other sensitive information by sniffing the network for XMPP traffic.
An issue was discovered in certain Apple products. iOS before 10.3 is affected. The issue involves the "iTunes Store" component. It allows man-in-the-middle attackers to modify the client-server data stream to iTunes sandbox web services by leveraging use of cleartext HTTP.
Incorrect access control in TP-Link Tapo before v3.1.315 allows attackers to access user credentials in plaintext.
An issue was discovered in Sesami Cash Point & Transport Optimizer (CPTO) version 6.3.8.6 (#718), allows remote attackers to obtain sensitive information via transmission of unencrypted, cleartext credentials during Password Reset feature.
IBM Spectrum Protect Plus information disclosure
IBM Spectrum Protect Plus 10.1.0 through 10.1.12 discloses sensitive information due to unencrypted data being used in the communication flow between Spectrum Protect Plus vSnap and its agents. An attacker could obtain information using main in the middle techniques. IBM X-Force ID: 182106.
HCL BigFix Insights for Vulnerability Remediation (IVR) is vulnerable to improper certificate validation
Insights for Vulnerability Remediation (IVR) is vulnerable to man-in-the-middle attacks that may lead to information disclosure. This requires privileged network access.
ICSA-22-053-02 GE Proficy CIMPLICITY-Cleartext
The affected product is vulnerable due to cleartext transmission of credentials seen in the CIMPLICITY network, which can be easily spoofed and used to log in to make operational changes to the system.
Rockwell Automation ISaGRAF5 Runtime Cleartext Transmission of Sensitive Information
ISaGRAF Workbench communicates with Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x using TCP/IP. This communication protocol provides various file system operations, as well as the uploading of applications. Data is transferred over this protocol unencrypted, which could allow a remote unauthenticated attacker to upload, read, and delete files.
3.2.5 CLEARTEXT TRANSMISSION OF SENSITIVE INFORMATION CWE-319
LRM version 2.4 and lower does not implement TLS encryption. A malicious actor can MITM attack sensitive data in-transit, including credentials.
AutomationDirect Stride Field I/O Cleartext Transmission of Sensitive Information
Any attempt (good or bad) to log into AutomationDirect Stride Field I/O with a web browser may result in the device responding with its password in the communication packets.
Fresenius Kabi Agilia Connect Infusion System use of a broken or risky cryptographic algorithm
Fresenius Kabi Agilia Link + version 3.0 does not enforce transport layer encryption. Therefore, transmitted data may be sent in cleartext. Transport layer encryption is offered on Port TCP/443, but the affected service does not perform an automated redirect from the unencrypted service on Port TCP/80 to the encrypted service.
GE UR family exposure of sensitive information to an unauthorized actor
GE UR firmware versions prior to version 8.1x web server interface is supported on UR over HTTP protocol. It allows sensitive information exposure without authentication.
Delta Electronics DIAEnergie CLEARTEXT Transmission of Sensitive Information
Delta Electronics DIAEnergie (Version 1.7.5 and prior) is vulnerable to cleartext transmission as the web application runs by default on HTTP. This could allow an attacker to remotely read transmitted information between the client and product.