CVE-2022-40282

The web server of Hirschmann BAT-C2 before 09.13.01.00R04 allows authenticated command injection. This allows an authenticated attacker to pass commands to the shell of the system because the dir parameter of the FsCreateDir Ajax function is not sufficiently sanitized. The vendor's ID is BSECV-2022-21.

CVSS 3.1 · 8.8 High EPSS 4.2% KEV · Not listed
Vendors
CVE-2017-11400

An issue has been discovered on the Belden Hirschmann Tofino Xenon Security Appliance before 03.2.00. An incomplete firmware signature allows a local attacker to upgrade the equipment (kernel, file system) with unsigned, attacker-controlled, data. This occurs because the appliance_config file is signed but the .tar.sec file is unsigned.

CVSS 3.0 · 6.8 Medium EPSS < 1% KEV · Not listed
Vendors
CVE-2017-11402

An issue has been discovered on the Belden Hirschmann Tofino Xenon Security Appliance before 03.2.00. Design flaws in OPC classic and in custom netfilter modules allow an attacker to remotely activate rules on the firewall and to connect to any TCP port of a protected asset, thus bypassing the firewall. The attack methodology is a crafted OPC dynamic port shift.

CVSS 3.0 · 9.8 Critical EPSS 1.5% KEV · Not listed
Vendors
CVE-2016-2509

The password-sync feature on Belden Hirschmann Classic Platform switches L2B before 05.3.07 and L2E, L2P, L3E, and L3P before 09.0.06 sets an SNMP community to the same string as the administrator password, which allows remote attackers to obtain sensitive information by sniffing the network.

CVSS 3.0 · 5.3 Medium EPSS < 1% KEV · Not listed
Vendors
CVE-2021-30066

On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, an arbitrary firmware image can be loaded because firmware signature verification (for a USB stick) can be bypassed. NOTE: this issue exists because of an incomplete fix of CVE-2017-11400.

CVE-2021-30065

On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, crafted ModBus packets can bypass the ModBus enforcer. NOTE: this issue exists because of an incomplete fix of CVE-2017-11401.

CVE-2021-30064

On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, an SSH login can succeed with hardcoded default credentials (if the device is in the uncommissioned state).

CVE-2021-27734

Hirschmann HiOS 07.1.01, 07.1.02, and 08.1.00 through 08.5.xx and HiSecOS 03.3.00 through 03.5.01 allow remote attackers to change the credentials of existing users.

CVSS 3.1 · 9.8 Critical EPSS 1.3% KEV · Not listed
Vendors
CVE-2020-9307

Hirschmann OS2, RSP, and RSPE devices before HiOS 08.3.00 allow a denial of service. An unauthenticated, adjacent attacker can cause an infinite loop on one of the HSR ring ports of the device. This effectively breaks the redundancy of the HSR ring. If the attacker can perform the same attack on a second device, the ring is broken into two parts (thus disrupting communication between devices in the different parts).

CVSS 3.1 · 6.5 Medium EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2020-6994

A buffer overflow vulnerability was found in some devices of Hirschmann Automation and Control HiOS and HiSecOS. The vulnerability is due to improper parsing of URL arguments. An attacker could exploit this vulnerability by specially crafting HTTP requests to overflow an internal buffer. The following devices using HiOS Version 07.0.02 and lower are affected: RSP, RSPE, RSPS, RSPL, MSP, EES, EES, EESX, GRS, OS, RED. The following devices using HiSecOS Version 03.2.00 and lower are affected: EAGLE20/30.

CVSS 3.1 · 9.8 Critical EPSS 1.6% KEV · Not listed