CVE-2025-60023

AutomationDirect Productivity Suite Relative Path Traversal

A relative path traversal vulnerability was discovered in Productivity Suite software version 4.4.1.19. The vulnerability allows an unauthenticated remote attacker to interact with the ProductivityService PLC simulator and delete arbitrary directories on the target machine.

CVSS 4.0 · 6.3 Medium EPSS < 1% KEV · Not listed
Products
P1-540 P1-550 P2-550 and 5 more
CVE-2025-59776

AutomationDirect Productivity Suite Relative Path Traversal

A relative path traversal vulnerability was discovered in Productivity Suite software version 4.4.1.19. The vulnerability allows an unauthenticated remote attacker to interact with the ProductivityService PLC simulator and create arbitrary directories on the target machine.

CVSS 4.0 · 6.3 Medium EPSS < 1% KEV · Not listed
Products
P1-540 P1-550 P2-550 and 5 more
CVE-2025-59484

AutomationDirect CLICK PLUS Use of a Broken or Risky Cryptographic Algorithm

The use of a broken or risky cryptographic algorithm was discovered in firmware version 3.60 of the Click Plus PLC. The vulnerability relies on the fact that the software uses an insecure implementation of the RSA encryption algorithm.

CVSS 4.0 · 8.7 High EPSS < 1% KEV · Not listed
Products
CVE-2025-58473

AutomationDirect CLICK PLUS Improper Resource Shutdown or Release

An improper resource shutdown or release vulnerability has been identified in the Click Plus C2-03CPU-2 device running firmware version 3.60. The vulnerability allows an unauthenticated attacker to perform a denial-of-service attack by exhausting all available device sessions of the Click Programming Software.

CVSS 4.0 · 8.2 High EPSS < 1% KEV · Not listed
Products
CVE-2025-58456

AutomationDirect Productivity Suite Relative Path Traversal

A relative path traversal vulnerability was discovered in Productivity Suite software version 4.4.1.19. The vulnerability allows an unauthenticated remote attacker to interact with the ProductivityService PLC simulator and read arbitrary files on the target machine.

CVSS 4.0 · 8.2 High EPSS < 1% KEV · Not listed
Products
P1-540 P1-550 P2-550 and 5 more
CVE-2025-58429

AutomationDirect Productivity Suite Relative Path Traversal

A relative path traversal vulnerability was discovered in Productivity Suite software version 4.4.1.19. The vulnerability allows an unauthenticated remote attacker to interact with the ProductivityService PLC simulator and delete arbitrary files on the target machine.

CVSS 4.0 · 8.3 High EPSS < 1% KEV · Not listed
Products
P1-540 P1-550 P2-550 and 5 more
CVE-2025-58078

AutomationDirect Productivity Suite Relative Path Traversal

A relative path traversal vulnerability was discovered in Productivity Suite software version 4.4.1.19. The vulnerability allows an unauthenticated remote attacker to interact with the ProductivityService PLC simulator and write files with arbitrary data on the target machine.

CVSS 4.0 · 8.3 High EPSS < 1% KEV · Not listed
Products
P1-540 P1-550 P2-550 and 5 more
CVE-2025-58069

AutomationDirect CLICK PLUS Use of Hard-coded Cryptographic Key

The use of a hard-coded cryptographic key was discovered in firmware version 3.60 of the Click Plus PLC. The vulnerability relies on the fact that the software contains a hard-coded AES key used to protect the initial messages of a new KOPS session.

CVSS 4.0 · 6.9 Medium EPSS < 1% KEV · Not listed
Products
CVE-2024-11611

AutomationDirect C-More EA9 EAP9 File Parsing Memory Corruption Remote Code Execution Vulnerability

AutomationDirect C-More EA9 EAP9 File Parsing Memory Corruption Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of AutomationDirect C-More EA9. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of EAP9 files. The issue results from the lack of proper validation of user-supplied data, which can result in a memory corruption condition. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-24774.

CVSS 3.0 · 7.8 High EPSS < 1% KEV · Not listed
CVE-2024-11610

AutomationDirect C-More EA9 EAP9 File Parsing Memory Corruption Remote Code Execution Vulnerability

AutomationDirect C-More EA9 EAP9 File Parsing Memory Corruption Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of AutomationDirect C-More EA9. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of EAP9 files. The issue results from the lack of proper validation of user-supplied data, which can result in a memory corruption condition. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-24773.

CVSS 3.0 · 7.8 High EPSS < 1% KEV · Not listed
CVE-2024-11609

AutomationDirect C-More EA9 EAP9 File Parsing Stack-based Buffer Overflow Remote Code Execution Vulnerability

AutomationDirect C-More EA9 EAP9 File Parsing Stack-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of AutomationDirect C-More EA9. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of EAP9 files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-24772.

CVSS 3.0 · 7.8 High EPSS < 1% KEV · Not listed
CVE-2017-14020

In AutomationDirect CLICK Programming Software (Part Number C0-PGMSW) Versions 2.10 and prior; C-More Programming Software (Part Number EA9-PGMSW) Versions 6.30 and prior; C-More Micro (Part Number EA-PGMSW) Versions 4.20.01.0 and prior; Do-more Designer Software (Part Number DM-PGMSW) Versions 2.0.3 and prior; GS Drives Configuration Software (Part Number GSOFT) Versions 4.0.6 and prior; SL-SOFT SOLO Temperature Controller Configuration Software (Part Number SL-SOFT) Versions 1.1.0.5 and prior; and DirectSOFT Programming Software Versions 6.1 and prior, an uncontrolled search path element (DLL Hijacking) vulnerability has been identified. To exploit this vulnerability, an attacker could rename a malicious DLL to meet the criteria of the application, and the application would not verify that the DLL is correct. Once loaded by the application, the DLL could run malicious code at the privilege level of the application.

CVSS 3.0 · 7.8 High EPSS 1.1% KEV · Not listed
CVE-2022-2006

AutomationDirect C-more EA9 HMI Uncontrolled Search Path Element

AutomationDirect DirectLOGIC has a DLL vulnerability in the install directory that may allow an attacker to execute code during the installation process. This issue affects: AutomationDirect C-more EA9 EA9-T6CL versions prior to 6.73; EA9-T6CL-R versions prior to 6.73; EA9-T7CL versions prior to 6.73; EA9-T7CL-R versions prior to 6.73; EA9-T8CL versions prior to 6.73; EA9-T10CL versions prior to 6.73; EA9-T10WCL versions prior to 6.73; EA9-T12CL versions prior to 6.73; EA9-T15CL versions prior to 6.73; EA9-RHMI versions prior to 6.73; EA9-PGMSW versions prior to 6.73;

CVSS 3.1 · 7.8 High EPSS < 1% KEV · Not listed
CVE-2022-2485

AutomationDirect Stride Field I/O Cleartext Transmission of Sensitive Information

Any attempt (good or bad) to log into AutomationDirect Stride Field I/O with a web browser may result in the device responding with its password in the communication packets.

CVSS 3.1 · 9.6 Critical EPSS < 1% KEV · Not listed
CVE-2021-32980

Automation Direct CLICK PLC CPU Modules Authentication Bypass Using an Alternate Path or Channel

Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 does not protect against additional software programming connections. An attacker can connect to the PLC while an existing connection is already active.

CVSS 3.1 · 9.8 Critical EPSS 1.1% KEV · Not listed
CVE-2021-32978

Automation Direct CLICK PLC CPU Modules Plaintext Storage of a Password

The programming protocol allows for a previously entered password and lock state to be read by an attacker. If the previously entered password was successful, the attacker can then use the password to unlock Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00.

CVSS 3.1 · 7.5 High EPSS 1.0% KEV · Not listed
CVE-2021-32984

Automation Direct CLICK PLC CPU Modules Authentication Bypass Using an Alternate Path or Channel

All programming connections receive the same unlocked privileges, which can result in a privilege escalation. During the time Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 is unlocked by an authorized user, an attacker can connect to the PLC and read the project without authorization.

CVSS 3.1 · 9.8 Critical EPSS 1.1% KEV · Not listed
CVE-2021-32986

Automation Direct CLICK PLC CPU Modules Authentication Bypass Using an Alternate Path or Channel

After Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 is unlocked by an authorized user, the unlocked state does not timeout. If the programming software is interrupted, the PLC remains unlocked. All subsequent programming connections are allowed without authorization. The PLC is only relocked by a power cycle, or when the programming software disconnects correctly.

CVSS 3.1 · 9.8 Critical EPSS 1.1% KEV · Not listed
CVE-2021-32982

Automation Direct CLICK PLC CPU Modules Cleartext Transmission of Sensitive Information

Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 passwords are sent as plaintext during unlocking and project transfers. An attacker who has network visibility can observe the password exchange.

CVSS 3.1 · 7.5 High EPSS < 1% KEV · Not listed
CVE-2022-2005

AutomationDirect C-more EA9 HMI Cleartext Transmission

AutomationDirect C-more EA9 HTTP webserver uses an insecure mechanism to transport credentials from client to web server, which may allow an attacker to obtain the login credentials and login as a valid user. This issue affects: AutomationDirect C-more EA9 EA9-T6CL versions prior to 6.73; EA9-T6CL-R versions prior to 6.73; EA9-T7CL versions prior to 6.73; EA9-T7CL-R versions prior to 6.73; EA9-T8CL versions prior to 6.73; EA9-T10CL versions prior to 6.73; EA9-T10WCL versions prior to 6.73; EA9-T12CL versions prior to 6.73; EA9-T15CL versions prior to 6.73; EA9-RHMI versions prior to 6.73; EA9-PGMSW versions prior to 6.73;

CVSS 3.1 · 7.5 High EPSS < 1% KEV · Not listed