CVE-2025-0477

Rockwell Automation FactoryTalk® AssetCentre Data Exposure Vulnerability

An encryption vulnerability exists in all versions prior to V15.00.001 of Rockwell Automation FactoryTalk® AssetCentre. The vulnerability exists due to a weak encryption methodology and could allow a threat actor to extract passwords belonging to other users of the application.

CVSS 4.0 · 9.3 Critical EPSS < 1% KEV · Not listed
CVE-2025-0497

Rockwell Automation FactoryTalk® AssetCentre Data Exposure Vulnerability

A data exposure vulnerability exists in all versions prior to V15.00.001 of Rockwell Automation FactoryTalk® AssetCentre. The vulnerability exists due to storing credentials in the configuration file of EventLogAttachmentExtractor, ArchiveExtractor, LogCleanUp, or ArchiveLogCleanUp packages.

CVSS 4.0 · 7.3 High EPSS < 1% KEV · Not listed
CVE-2025-0498

Rockwell Automation FactoryTalk® AssetCentre Data Exposure Vulnerability

A data exposure vulnerability exists in all versions prior to V15.00.001 of Rockwell Automation FactoryTalk® AssetCentre. The vulnerability exists due to insecure storage of FactoryTalk® Security user tokens, which could allow a threat actor to steal a token and, impersonate another user.

CVSS 4.0 · 7 High EPSS < 1% KEV · Not listed
CVE-2025-7972

Rockwell Automation FactoryTalk® Linx Network Browser Security Bypass Vulnerability

A security issue exists within the FactoryTalk Linx Network Browser. By modifying the process.env.NODE_ENV to ‘development’, the attacker can disable FTSP token validation. This bypass allows access to create, update, and delete FTLinx drivers.

CVSS 4.0 · 8.4 High EPSS < 1% KEV · Not listed
Products
CVE-2025-9063

Rockwell Automation PanelView Plus 7 Performance Series B Authentication Bypass

An authentication bypass security issue exists within FactoryTalk View Machine Edition Web Browser ActiveX control. Exploitation of this vulnerability allows unauthorized access to the PanelView Plus 7 Series B, including access to the file system, retrieval of diagnostic information, event logs, and more.

CVSS 4.0 · 7 High EPSS < 1% KEV · Not listed
CVE-2025-9064

Rockwell Automation FactoryTalk View Machine Edition Path Traversal

A path traversal security issue exists within FactoryTalk View Machine Edition, allowing unauthenticated attackers on the same network as the device to delete any file within the panels operating system. Exploitation of this vulnerability is dependent on the knowledge of filenames to be deleted.

CVSS 4.0 · 8.7 High EPSS < 1% KEV · Not listed
CVE-2025-9067

Rockwell Automation FactoryTalk® Linx Privilege Escalation Vulnerabilities

A security issue exists within the x86 Microsoft Installer File (MSI), installed with FTLinx. Authenticated attackers with valid Windows user credentials can initiate a repair and hijack the resulting console window. This allows the launching of a command prompt running with SYSTEM-level privileges, allowing full access to all files, processes, and system resources.

CVSS 4.0 · 8.5 High EPSS < 1% KEV · Not listed
CVE-2025-9161

Rockwell Automation FactoryTalk Optix Remote Code Execution Vulnerability

A security issue exists within FactoryTalk Optix MQTT broker due to the lack of URI sanitization. This flaw enables the loading of remote Mosquito plugins, which can be used to achieve remote code execution.

CVSS 4.0 · 7.3 High EPSS < 1% KEV · Not listed
CVE-2024-21914

Rockwell Automation - FactoryTalk® View ME on PanelView™ Plus 7 Boot Terminal lack Security Protections

A vulnerability exists in the affected product that allows a malicious user to restart the Rockwell Automation PanelView™ Plus 7 terminal remotely without security protections. If the vulnerability is exploited, it could lead to the loss of view or control of the PanelView™ product.

CVSS 3.1 · 5.3 Medium EPSS < 1% KEV · Not listed
Products
CVE-2025-7970

Rockwell Automation FactoryTalk Activation Manager Lack of Encryption Vulnerability

A security issue exists within FactoryTalk Activation Manager. An error in the implementation of cryptography within the software could allow attackers to decrypt traffic. This could result in data exposure, session hijacking, or full communication compromise.

CVSS 4.0 · 8.7 High EPSS < 1% KEV · Not listed
CVE-2025-9364

Rockwell Automation FactoryTalk® Analytics™ LogixAI® Exposed Redis DB

An open database issue exists in the affected product and version. The security issue stems from an over permissive Redis instance. This could result in an attacker on the intranet accessing sensitive data and potential alteration of data.

CVSS 4.0 · 8.7 High EPSS < 1% KEV · Not listed
CVE-2024-7513

Rockwell Automation FactoryTalk® View Site Edition Code Execution Vulnerability via File Permissions

CVE-2024-7513 IMPACT A code execution vulnerability exists in the affected product. The vulnerability occurs due to improper default file permissions allowing any user to edit or replace files, which are executed by account with elevated permissions.

CVSS 4.0 · 8.5 High EPSS 1.7% KEV · Not listed
Products
CVE-2022-3158

Rockwell Automation FactoryTalk VantagePoint versions 8.0, 8.10, 8.20, 8.30, 8.31 are vulnerable to an input validation vulnerability. The FactoryTalk VantagePoint SQL Server lacks input validation when users enter SQL statements to retrieve information from the back-end database. If successfully exploited, this could allow a user with basic user privileges to perform remote code execution on the server.

CVSS 3.1 · 8.8 High EPSS 4.0% KEV · Not listed
CVE-2022-38743

Rockwell Automation FactoryTalk VantagePoint versions 8.0, 8.10, 8.20, 8.30, 8.31 are vulnerable to an improper access control vulnerability. The FactoryTalk VantagePoint SQL Server account could allow a malicious user with read-only privileges to execute SQL statements in the back-end database. If successfully exploited, this could allow the attacker to execute arbitrary code and gain access to restricted data.

CVSS 3.1 · 8.8 High EPSS 1.9% KEV · Not listed
CVE-2022-38744

FactoryTalk Alarm and Events Server Vulnerable to Denial-Of-Service Attack

An unauthenticated attacker with network access to a victim's Rockwell Automation FactoryTalk Alarm and Events service could open a connection, causing the service to fault and become unavailable. The affected port could be used as a server ping port and uses messages structured with XML.

CVSS 3.1 · 7.5 High EPSS 1.3% KEV · Not listed
CVE-2017-14022

An Improper Input Validation issue was discovered in Rockwell Automation FactoryTalk Alarms and Events, Version 2.90 and earlier. An unauthenticated attacker with remote access to a network with FactoryTalk Alarms and Events can send a specially crafted set of packets packet to Port 403/TCP (the history archiver service), causing the service to either stall or terminate.

CVSS 3.0 · 7.5 High EPSS 4.2% KEV · Not listed
CVE-2020-14481

The DeskLock tool provided with FactoryTalk View SE uses a weak encryption algorithm that may allow a local, authenticated attacker to decipher user credentials, including the Windows user or Windows DeskLock passwords. If the compromised user has an administrative account, an attacker could gain full access to the user’s operating system and certain components of FactoryTalk View SE.

CVSS 3.1 · 7.8 High EPSS < 1% KEV · Not listed
Products
CVE-2020-14480

Due to usernames/passwords being stored in plaintext in Random Access Memory (RAM), a local, authenticated attacker could gain access to certain credentials, including Windows Logon credentials.

CVSS 3.1 · 5.5 Medium EPSS < 1% KEV · Not listed
Products
CVE-2020-14478

IMPROPER RESTRICTION OF XML EXTERNAL ENTITY REFERENCE CWE-611

A local, authenticated attacker could use an XML External Entity (XXE) attack to exploit weakly configured XML files to access local or remote content. A successful exploit could potentially cause a denial-of-service condition and allow the attacker to arbitrarily read any local file via system-level services.

CVSS 3.1 · 7.1 High EPSS < 1% KEV · Not listed
CVE-2021-32960

Rockwell Automation FactoryTalk Services Platform Protection Mechanism Failure

Rockwell Automation FactoryTalk Services Platform v6.11 and earlier, if FactoryTalk Security is enabled and deployed contains a vulnerability that may allow a remote, authenticated attacker to bypass FactoryTalk Security policies based on the computer name. If successfully exploited, this may allow an attacker to have the same privileges as if they were logged on to the client machine.

CVSS 3.1 · 8.5 High EPSS 2.4% KEV · Not listed