Search vulnerabilities

Results 33

Export CSV
CVE-2023-44014

Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain multiple stack overflows in the formSetMacFilterCfg function via the macFilterType and deviceList parameters.

CVSS 3.1 · 8.8 High EPSS 1.1% KEV · Not listed
Vendors
CVE-2023-37144

Tenda AC10 v15.03.06.26 was discovered to contain a command injection vulnerability via the mac parameter in the function formWriteFacMac.

CVSS 3.1 · 9.8 Critical EPSS 2.4% KEV · Not listed
Vendors
Products
CVE-2022-26243

Tenda AC10-1200 v15.03.06.23_EN was discovered to contain a buffer overflow in the setSmartPowerManagement function.

CVSS 3.1 · 7.5 High EPSS 1.2% KEV · Not listed
Vendors
Products
CVE-2021-45401

A Command injection vulnerability exists in Tenda AC10U AC1200 Smart Dual-band Wireless Router AC10U V1.0 Firmware V15.03.06.49_multi via the setUsbUnload functionality. The vulnerability is caused because the client controlled "deviceName" value is passed directly to the "doSystemCmd" function.

CVSS 3.1 · 9.8 Critical EPSS 2.5% KEV · Not listed
Vendors
CVE-2021-38772

Tenda AC10-1200 v15.03.06.23_EN was discovered to contain a buffer overflow via the list parameter in the fromSetIpMacBind function.

CVSS 3.1 · 7.5 High EPSS 1.2% KEV · Not listed
Vendors
Products
CVE-2021-38278

Tenda AC10-1200 v15.03.06.23_EN was discovered to contain a buffer overflow via the urls parameter in the saveParentControlInfo function.

CVSS 3.1 · 9.8 Critical EPSS 1.4% KEV · Not listed
Vendors
Products
CVE-2020-22079

Stack-based buffer overflow in Tenda AC-10U AC1200 Router US_AC10UV1.0RTL_V15.03.06.48_multi_TDE01 allows remote attackers to execute arbitrary code via the timeZone parameter to goform/SetSysTimeCfg.

CVSS 3.1 · 9.8 Critical EPSS 4.2% KEV · Not listed
Vendors
Products
Ac10u Ac10u Firmware Ac9 and 1 more
CVE-2018-16334

An issue was discovered on Tenda AC9 V15.03.05.19(6318)_CN and AC10 V15.03.06.23_CN devices. The mac parameter in a POST request is used directly in a doSystemCmd call, causing OS command injection.

CVSS 3.0 · 8.8 High EPSS 3.6% KEV · Not listed
Vendors
Products
Ac10 Ac10 Firmware Ac9 and 1 more
CVE-2018-16333

An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server. While processing the ssid parameter for a POST request, the value is directly used in a sprintf call to a local variable placed on the stack, which overrides the return address of the function, causing a buffer overflow.

CVSS 3.0 · 7.5 High EPSS 1.7% KEV · Not listed
Vendors
Products
Ac10 Ac10 Firmware Ac15 and 7 more
CVE-2018-14492

Tenda AC7 through V15.03.06.44_CN, AC9 through V15.03.05.19(6318)_CN, and AC10 through V15.03.06.23_CN devices have a Stack-based Buffer Overflow via a long limitSpeed or limitSpeedup parameter to an unspecified /goform URI.

CVSS 3.0 · 7.5 High EPSS 1.1% KEV · Not listed
Vendors
Products
Ac10 Ac10 Firmware Ac15 and 7 more