Search vulnerabilities

Results 417

Export CSV
CVE-2020-12027

Rockwell Automation FactoryTalk View SE

All versions of FactoryTalk View SE disclose the hostnames and file paths for certain files within the system. A remote, authenticated attacker may be able to leverage this information for reconnaissance efforts. Rockwell Automation recommends enabling built in security features found within FactoryTalk View SE. Users should follow guidance found in knowledge base articles 109056 and 1126943 to set up IPSec and/or HTTPs.

CVSS 3.1 · 4.3 Medium EPSS 53.0% KEV · Not listed
Products
CVE-2020-12025

Rockwell Automation Logix Designer Studio 5000 Versions 32.00, 32.01, and 32.02 vulnerable to an xml external entity (XXE) vulnerability, which may allow an attacker to view hostnames or other resources from the program.

CVSS 3.1 · 3.3 Low EPSS 1.5% KEV · Not listed
CVE-2020-12005

FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. A vulnerability exists in the communication function that enables users to upload EDS files by FactoryTalk Linx. This may allow an attacker to upload a file with bad compression, consuming all the available CPU resources, leading to a denial-of-service condition.

CVSS 3.1 · 7.5 High EPSS 1.8% KEV · Not listed
CVE-2020-12003

FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. An exposed API call allows users to provide files to be processed without sanitation. This may allow an attacker to use specially crafted requests to traverse the file system and expose sensitive data on the local hard drive.

CVSS 3.1 · 7.5 High EPSS 5.4% KEV · Not listed
CVE-2020-12001

FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. The parsing mechanism that processes certain file types does not provide input sanitation. This may allow an attacker to use specially crafted files to traverse the file system and modify or expose sensitive data or execute arbitrary code.

CVSS 3.1 · 9.8 Critical EPSS 11.8% KEV · Not listed
CVE-2020-11999

FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. An exposed API call allows users to provide files to be processed without sanitation. This may allow an attacker to specify a filename to execute unauthorized code and modify files or data.

CVSS 3.1 · 8.1 High EPSS 2.8% KEV · Not listed
CVE-2020-10642

In Rockwell Automation RSLinx Classic versions 4.11.00 and prior, an authenticated local attacker could modify a registry key, which could lead to the execution of malicious code using system privileges when opening RSLinx Classic.

CVSS 3.1 · 7.8 High EPSS < 1% KEV · Not listed
Products
CVE-2019-6553

A vulnerability was found in Rockwell Automation RSLinx Classic versions 4.10.00 and prior. An input validation issue in a .dll file of RSLinx Classic where the data in a Forward Open service request is passed to a fixed size buffer, allowing an attacker to exploit a stack-based buffer overflow condition.

CVSS 3.1 · 9.8 Critical EPSS 66.3% KEV · Not listed
Products
CVE-2019-10970

In Rockwell Automation PanelView 5510 (all versions manufactured before March 13, 2019 that have never been updated to v4.003, v5.002, or later), a remote, unauthenticated threat actor with access to an affected PanelView 5510 Graphic Display, upon successful exploit, may boot-up the terminal and gain root-level access to the device’s file system.

CVSS 3.1 · 9.8 Critical EPSS 4.6% KEV · Not listed
CVE-2018-8843

Rockwell Automation Arena versions 15.10.00 and prior contains a use after free vulnerability caused by processing specially crafted Arena Simulation Software files that may cause the software application to crash, potentially losing any unsaved data..

CVSS 3.0 · 5.5 Medium EPSS 2.0% KEV · Not listed
Products
CVE-2018-19282

Rockwell Automation PowerFlex 525 AC Drives 5.001 and earlier allow remote attackers to cause a denial of service by crashing the Common Industrial Protocol (CIP) network stack. The vulnerability allows the attacker to crash the CIP in a way that it does not accept new connections, but keeps the current connections active, which can prevent legitimate users from recovering control.

CVSS 3.0 · 9.8 Critical EPSS 5.6% KEV · Not listed
CVE-2018-19016

Rockwell Automation EtherNet/IP Web Server Modules 1756-EWEB (includes 1756-EWEBK) Version 5.001 and earlier, and CompactLogix 1768-EWEB Version 2.005 and earlier. A remote attacker could send a crafted UDP packet to the SNMP service causing a denial-of-service condition to occur until the affected product is restarted.

CVSS 3.0 · 7.5 High EPSS 3.2% KEV · Not listed
CVE-2018-18981

In Rockwell Automation FactoryTalk Services Platform 2.90 and earlier, a remote unauthenticated attacker could send numerous crafted packets to service ports resulting in memory consumption that could lead to a partial or complete denial-of-service condition to the affected services.

CVSS 3.0 · 7.5 High EPSS 3.9% KEV · Not listed
CVE-2018-14829

Rockwell Automation RSLinx Classic Versions 4.00.01 and prior. This vulnerability may allow a remote threat actor to intentionally send a malformed CIP packet to Port 44818, causing the software application to stop responding and crash. This vulnerability also has the potential to exploit a buffer overflow condition, which may allow the threat actor to remotely execute arbitrary code.

CVSS 3.0 · 9.8 Critical EPSS 16.1% KEV · Not listed
Products
CVE-2018-14827

Rockwell Automation RSLinx Classic Versions 4.00.01 and prior. A remote, unauthenticated threat actor may intentionally send specially crafted Ethernet/IP packets to Port 44818, causing the software application to stop responding and crash. The user must restart the software to regain functionality.

CVSS 3.0 · 7.5 High EPSS 3.8% KEV · Not listed
Products
CVE-2018-14821

Rockwell Automation RSLinx Classic Versions 4.00.01 and prior. This vulnerability may allow a remote, unauthenticated threat actor to intentionally send a malformed CIP packet to Port 44818, causing the RSLinx Classic application to terminate. The user will need to manually restart the software to regain functionality.

CVSS 3.0 · 7.5 High EPSS 4.5% KEV · Not listed
Products
CVE-2018-10619

An unquoted search path or element in RSLinx Classic Versions 3.90.01 and prior and FactoryTalk Linx Gateway Versions 3.90.00 and prior may allow an authorized, but non-privileged local user to execute arbitrary code and allow a threat actor to escalate user privileges on the affected workstation.

CVSS 3.0 · 7.8 High EPSS 2.7% KEV · Not listed