SAPCAR - version 7.22, does not contain sufficient input validation on the SAPCAR archive. As a result, the SAPCAR process may crash, and the attacker may obtain privileged access to the system.
Export limit exceeded: 426252 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search vulnerabilities
Error message discloses internal path
When handling a mismatched pre-authentication cookie, the application leaks the internal error message in the response, which contains the Splunk Enterprise local system path. The vulnerability impacts Splunk Enterprise versions before 8.1.0.
On 1.0.x versions prior to 1.0.1, systems running F5OS-A software may expose certain registry ports externally. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated
Remote Code Execution (RCE)
The package com.google.cloud.tools:jib-core before 0.22.0 are vulnerable to Remote Code Execution (RCE) via the isDockerInstalled function, due to attempting to execute input.
Improper Input Validation
The package url-js before 2.1.0 are vulnerable to Improper Input Validation due to improper parsing, which makes it is possible for the hostname to be spoofed. http://\\\\\\\\localhost and http://localhost are the same URL. However, the hostname is not parsed as localhost, and the backslash is reflected as it is.
Information Exposure vulnerability in Galaxy Watch3 Plugin prior to version 2.2.09.22012751 allows attacker to access password information of connected WiFiAp in the log
Information Exposure vulnerability in Watch Active2 Plugin prior to version 2.2.08.22012751 allows attacker to access password information of connected WiFiAp in the log
Information Exposure vulnerability in Watch Active Plugin prior to version 2.2.07.22012751 allows attacker to access password information of connected WiFiAp in the log
Information Exposure vulnerability in Galaxy Watch Plugin prior to version 2.2.05.22012751 allows attacker to access password information of connected WiFiAp in the log
Information Exposure vulnerability in Galaxy S3 Plugin prior to version 2.2.03.22012751 allows attacker to access password information of connected WiFiAp in the log
Information Exposure vulnerability in Galaxy Watch Plugin prior to version 2.2.05.220126741 allows attackers to access user information in log.
Improper boundary check in UWB stack prior to SMR Mar-2022 Release 1 allows arbitrary code execution.
GTA URLs issued by LMM WEB API may leak information
Information Exposure Through Query Strings in GET Request vulnerability in LMM API of Secomea GateManager allows system administrator to hijack connection. This issue affects: Secomea GateManager all versions prior to 9.7.
Information leak via device availability query function
Information Exposure vulnerability in web UI of Secomea GateManager allows logged in user to query devices outside own scope.
Apache APISIX: the body_schema check in request-validation plugin can be bypassed
In Apache APISIX before 2.13.0, when decoding JSON with duplicate keys, lua-cjson will choose the last occurred value as the result. By passing a JSON with a duplicate key, the attacker can bypass the body_schema validation in the request-validation plugin. For example, `{"string_payload":"bad","string_payload":"good"}` can be used to hide the "bad" input. Systems satisfy three conditions below are affected by this attack: 1. use body_schema validation in the request-validation plugin 2. upstream application uses a special JSON library that chooses the first occurred value, like jsoniter or gojay 3. upstream application does not validate the input anymore. The fix in APISIX is to re-encode the validated JSON input back into the request body at the side of APISIX. Improper Input Validation vulnerability in __COMPONENT__ of Apache APISIX allows an attacker to __IMPACT__. This issue affects Apache APISIX Apache APISIX version 2.12.1 and prior versions.
A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. Affected devices do not properly validate the HTTP headers of incoming requests. This could allow an unauthenticated remote attacker to crash affected devices.
Improper Input Validation in MODEM
Memory corruption in modem due to improper length check while copying into memory
ASUS RT-AC86U - Improper Input Validation
ASUS RT-AC86U has improper user request handling, which allows an unauthenticated LAN attacker to cause a denial of service by sending particular request a server-to-client reply attempt.
Microprogram parking lot management system - Exposure of Sensitive Information to an Unauthorized Actor
Microprogram’s parking lot management system is vulnerable to sensitive information exposure. An unauthorized remote attacker can input specific URLs to acquire partial system configuration information.
FreeTAKServer-UI v1.9.8 was discovered to leak sensitive API and Websocket keys.