Search vulnerabilities

Results 28

Export CSV
CVE-2022-45648

Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the devName parameter in the formSetDeviceName function.

CVSS 3.1 · 7.5 High EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2022-45661

Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the time parameter in the setSmartPowerManagement function.

CVSS 3.1 · 7.5 High EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2022-45660

Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the schedStartTime parameter in the setSchedWifi function.

CVSS 3.1 · 7.5 High EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2022-45659

Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the wpapsk_crypto parameter in the fromSetWirelessRepeat function.

CVSS 3.1 · 7.5 High EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2022-45658

Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the schedEndTime parameter in the setSchedWifi function.

CVSS 3.1 · 7.5 High EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2022-45657

Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the list parameter in the fromSetIpMacBind function.

CVSS 3.1 · 7.5 High EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2022-45650

Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the firewallEn parameter in the formSetFirewallCfg function.

CVSS 3.1 · 7.5 High EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2022-45649

Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the endIp parameter in the formSetPPTPServer function.

CVSS 3.1 · 7.5 High EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2022-45645

Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the deviceMac parameter in the addWifiMacFilter function.

CVSS 3.1 · 7.5 High EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2022-45656

Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the time parameter in the fromSetSysTime function.

CVSS 3.1 · 7.5 High EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2022-45655

Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the timeZone parameter in the form_fast_setting_wifi_set function.

CVSS 3.1 · 7.5 High EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2022-45654

Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the ssid parameter in the form_fast_setting_wifi_set function.

CVSS 3.1 · 7.5 High EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2022-45653

Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the page parameter in the fromNatStaticSetting function.

CVSS 3.1 · 7.5 High EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2022-45652

Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the startIp parameter in the formSetPPTPServer function.

CVSS 3.1 · 9.1 Critical EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2022-45651

Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the list parameter in the formSetVirtualSer function.

CVSS 3.1 · 9.1 Critical EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2022-45647

Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the limitSpeed parameter in the formSetClientState function.

CVSS 3.1 · 7.5 High EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2022-45646

Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the limitSpeedUp parameter in the formSetClientState function.

CVSS 3.1 · 7.5 High EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2022-45644

Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the deviceId parameter in the formSetClientState function.

CVSS 3.1 · 7.5 High EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2022-45643

Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the deviceId parameter in the addWifiMacFilter function.

CVSS 3.1 · 7.5 High EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2023-24332

A stack overflow vulnerability in Tenda AC6 with firmware version US_AC6V5.0re_V03.03.02.01_cn_TDC01 allows attackers to run arbitrary commands via crafted POST request to /goform/PowerSaveSet.

CVSS 3.1 · 8.1 High EPSS < 1% KEV · Not listed
Vendors